Publish Time: 2021-09-22 Origin: Site
With the extension of people's life span and the demand for orthopedic implants by some young patients, there is a high demand for manufacturers to produce long-lasting orthopedic implants. Surgical drills are used during orthopedic implant surgery, and surgical drills will be introduced in this article.
l Introduction of surgical drills.
l All products of Jiangsu Jinlu Group Medical Device Co., Ltd.
Medical surgical drills are commonly used instruments for orthopedic patients in surgery. The introduction of how to use and maintain them correctly is as follows:
1 How to use
1.1 To load and unload the battery of the surgical drill during the operation, turn the knob clockwise into place, remove the handle cover, put on the isolation channel, hold the battery with a sterile gauze bag, place the battery head down, and align the groove with the groove in the handle Insert it, remove the isolation channel cover, and turn the knob counterclockwise to place.
1.2 Forward and reverse rotation of the surgical drill Turn the back-end knob of the main unit clockwise to R, which means forward rotation, and turn the back-end knob of the main unit counterclockwise to L, which means reverse rotation.
2 Charging the battery
2.1 Connect the surgical drill charger to the power source, and the power indicator red light flashes three times.
2.2 Place the battery of the surgical drill with the small end down, and insert the pin seat on the battery with the pin on the charger.
3 Disinfection
3.1 Put the main body of the surgical drill on a stainless steel mesh rack and sterilize it at 135 degrees for 20 minutes.
3.2 The charger and battery of the surgical drill do not need to be disinfected, and high temperature disinfection is strictly prohibited.
4 cleaning
4.1Surgical drill chargers and batteries can also be wiped clean and stored in this way.
5 matters needing attention
5.1 Surgical drill is a short-term operation product, and it cannot be used for a long time with full operation. Each operation time is 10 minutes. The hand washing nurse should remind the doctor to pay attention.
5.2 High temperature and high pressure disinfection of the battery is strictly prohibited. The battery should not be left in the machine for a long time. After the operation, take the battery out and put it in the packing box. For the battery that is not used for a long time, the surgical drill needs to be charged once a month to prevent the plate from aging.
5.3 The power cord of the surgical drill charger should not be corroded by oils, chemical solutions, etc. or mechanically damaged. Once found, it must be replaced immediately.
5.4 The instrument nurse must be familiar with the functions of the surgical drill and the correct installation and use. The instruments are expensive, and the maintenance methods are particularly important.
Jiangsu Jinlu Group Medical Device Co., Ltd. is located in Zhangjiagang, an international trade port on the lower reaches of the Yangtze River. The company has 62 years of experience in the manufacture of orthopedic implants and equipment. If you are interested in our company's surgical drill products, you can go to our company to check. We will provide the best surgical drill products and services.